HM 150.12 Vertical Flow From A Tank Didactic Equipment Vocational Education Equipment Fluid Mechanics Lab Equipment
Determination of pressure losses and contraction coefficient for different outlet contours Features - determination of the diameter and velocity of the outlet jet - study of openings with different inlet and outlet contours - determining the contraction coefficient Learning objectives/experiments - study of the outlet jet (diameter, velocity) - determination of pressure losses and contraction coefficient for different outlet contours - determination of flow rate at different discharge heads Specification [1] study of pressure losses in vertical flows from tanks [2] determining the contraction coefficient for different contours and diameters [3] tank with adjustable overflow [4] 5 interchangeable inserts with different contours [5] measuring device for determining the jet diameter [6] Pitot tube for determining the total pressure [7] pressure display on twin tube manometers [8] flow rate determined by HM 150 base module [9] water supply using HM 150 base module or via laboratory supply Technical data Tank - capacity: approx. 13L - overflow height: max. 400mm - max. flow rate: 14L/min Inserts Inner diameters: d1=inlet, d2=outlet - 1x cylindrical hole, d=12mm - 1x outlet from the insert: cone d1=24mm, d2=12mm - 1x inlet to the insert: orifice plate d1=24mm, d2=12mm - 1x inlet to the insert: cone d1=30mm, d2=12mm - 1x inlet to the insert: rounded, d=12mm Measuring ranges - pressure: 500mmWC - jet radius: 0...10mm LxWxH: 400x400x830mm Weight: approx. 18kg